1.8kv AC-DC Photovoltaic XLPE Power Solar Cable
Overview Package size per unit product 100.00cm * 100.00cm * 100.00cm Gross weight per unit product 100.000kg 1.8kv AC-D
Description
Basic Info
Model NO. | power cable |
Insulation Material | XLPE |
Sheath Material | PVC |
Material Shape | Round Wire |
Wire Core Material | Bare Copper Wire |
Certification | ISO, CE, SABS |
Model | YJV |
Brand | Power Cable |
Standard | ASTM, IEC, DIN, CSA, BS... |
Product | 1.8kv AC-DC Solar XLPE Power Cable |
Color | Black, Blue or Any Other Color by Client |
Size | 2.5---630mm2 |
Transport Package | Export Wooden Drum or Wooden Steel Drum |
Specification | 1.8KV AC-DC SOLAR XLPE POWER CABLE |
Trademark | JP |
Origin | China |
HS Code | 8544601200 |
Production Capacity | 5000 Kilometers/Month |
Packaging & Delivery
Package size per unit product 100.00cm * 100.00cm * 100.00cm Gross weight per unit product 100.000kgProduct Description
1.8kv AC-DC Photovoltaic XLPE Power Solar CableProduct Description
Product Description
Standards of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power CableThe cable is manufactured according to IEC 60502.2, IEC 60502.1, AS/NZS 1429.1, AS/NZS 5000.1, BS 6622/7835, BS 5467, BS 6746, BS 6346, VDE 0276, ASTM, ABNT etc. It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.
Application of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
The electric cable is applied to transmit and distribute power in power transmission and distribution system of 1kV~35kV or lower. It is widely adopted in the fields including power, construction, industry, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial re-place of PVC insulation or XLPE power cable.
Type | Description | Applications |
N2XY/N2XSEY NA2XY/NA2XSEY | Cu or AL conductor XLPE insulated PVC sheathed power cables. | For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts. |
N2X2Y/N2XSE2Y NA2X2Y/NA2XSE2Y | Cu or AL conductor XLPE insulated PE sheathed power cables. | |
N2XBY/N2XSEBY NA2XBY/NA2XSEBY | Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables. | For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit. |
N2XB2Y/N2XSEB2Y NA2XB2Y/NA2XSEB2Y | Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables. | |
N2XRY/N2XSERY NA2XRY/NA2XSERY | Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables. | For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces. |
N2XR2Y/N2XSER2Y NA2XR2Y/NA2XSER2Y | Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables. |